[ Post New Message | Post Reply to this One | Send Private Email to Michael Feldman | Help ]

Response to Why do I get reticulation only with Tri-X ????????

from Michael Feldman (mfeldman@qwest.net)
Tri-X is definitely an older emulsion that is very sensitive to temp changes in processing. I had the same problem when I lived in Houston years ago, and all the films available then were highly subject to reticulation. To solve this problem, I recommend that you use a very fresh Rapid Fix for a maximum of 2 minutes, followed by a reasonably fresh hypo clearing product, followed by a wash that does not use running water. This wash can be accomplished by a change of water about 5 times (not running water). Obviously, the means having enough water for the 5 changes on hand at the correct temperature. By keeping the fix time to a minimum, you can get away with a non- running water wash. Using an acid stop bath will keep your fixer more fresh and allow you to take a few seconds off your fix time (less wash required).
(posted 8392 days ago)