Response to Development Chart 14 - New Delta 400

from David R. Williams (davidw@ca.ibm.com)
EI 320 in regular strength PMK for 16 minutes at 70F in Paterson small tank. Agitation by end-over-end tank inversions with continuous agitation for the first 30 seconds followed by 2 inversions every 15 seconds.