[ Post New Message | Post Reply to this One | Send Private Email to Tim Brown | Help ]

Response to pulling hp5 to iso 250

from Tim Brown (brownt@flash.net)
You say the lighting was flat, so don't reduce development time. EI 250 is only 2/3 stop, well within the lattitude of the film, variation in exposure meters, shutters, etc. 250 is the normal EI for some people. Develop as you normally do.
(posted 8405 days ago)