Otis E401, EML8/9

greenspun.com : LUSENET : Elevator Problem Discussion : One Thread

Does anybody know what to look for to find an error in motion logic state 8 or 9....

-- Keith Witherspoon (snowpea493@hotmail.com), March 15, 2002

Answers

mainly your 1M and 2M microswithes...

-- dayle (daylebrenda@iprimus.com.au), November 05, 2002.

This is quite a common fault, from memory check the following: Brake and Brake Switches, 1M and 2M microswitches,1CR UX and DX relays. The fault normally indicates that UX or DX has not pulled in, so check everything in these circuts (I've only ever worked on units with direct drives so I'm not sure if this also applies to units with MG sets) Hope this helps.

-- Ray (rayzo@iinet.net.au), February 15, 2003.

Replace or clean the relay i/o board!

-- Dan W (Danotis@aol.com), March 13, 2003.