bypass on a "401"greenspun.com : LUSENET : Elevator Problem Discussion : One Thread |
Hi guys I have a group of 6 elevators “401” on service These elevators when in full load still accepts landing call’s By pass routine looks like not working Any idée ? Jeff
-- Chris Uvyn (chrisuvyn@skynet.be), May 22, 2004
your load weighter is not turned on, or your loadcells have been dissconnected from the car processor.
-- Harry Cavanagh (Hcavanagh@aol.com), May 28, 2004.
LNS is not active for some reason? check 90% load switch or processor input